ENGLISH

 

 

Orte Power Pellet Air Heater 24-350 kW

Independent appliance with automatic lighter, self cleaning burner with efficiency over 92%.

 

Self-cleaning burner

The heater is being cleaned automatically thus warranting proper burning conditions and saving your effort.

 

Automatic lighting

The heater switches off automatically in the case when there is no more demand for heat. When the demand is detected further on, the heater will light automatically and start regular operation.

 

Economy

Pellets air heaters reduce heating costs compared to:

  • propane gas – up to 45%,
  • oil – up to 70%,
  • gas – up to 35%,

There is no need to instal or change already existing heating installation.

 

Ecology

Advanced control system, effective heat exchange, ecological fuel-pellets warrant low emissions of co2 and other environmentally hazardous substances. No inconvenient smells.

 

Usage

Warehouses, workshops, offices, houses, tents, events, sport halls and many others.

Orte Power Pellet Air Heaters can be used as a part of already existing or brand new air heating and ventilation/aircondition system in all types of buildings.

ORTE POWER Pellet Air Heater, model 24, 35, 45, 80, 130, 250, is  an advanced heating system burning pellets. The system includes the Air Heater (from 24 kW to 250 kW) together with the pellet burner, hopper and feeder. It is destined to heat small to middle-sized  buildings or spaces without central heating installation. The warmth produced by the Air Heater can be transmitted directly from the appliance (Orte Power 24 kW) or be leaded to a certain room through a pipe system (Orte Power 35-250 kW).

There are available types of the Orte Power heaters: 24, 35, 45, 80, 130, 250 kW, with the heated air flow rate between 1500 and 15200 m3/h. With such a wide performance range, the devices can be used not only in single-family houses, but also in much larger buildings e.g.: offices, office blocks, multi-family houses, warehouses, industry and sports halls, greenhouses, and other buildings where heat needs to be supplied quickly.

The Orte Power heaters can be used for heating and ventilation in the existing buildings with the traditional gravity ventilation, without exhaust ducts and/or a recuperator. Then the heat is transmitted through the flue that distributes air sideways or through intake ducts. The excessive used air is removed through the gravity ventilation ducts due to overpressure. The air is supplied to the heater in a mixed way: an external intake vent supplies fresh air and mixes it with the air returning through the internal intake vent from the heated premises.

Orte Power Pellet  Air Heater 24-250 kW TECHNICAL INFO:

 

TYPE Orte Power 24 Orte Power  35 Orte Power  45 Orte Power  80 Orte Power  130 Orte Power  250
TECHNICAL DETAILS
Power delivered with fuel (kW) 24 35 45,5 80 131,1 246
Power nominal/max. 21 30 38,4 70 117 202,2
Power partial/min. 7 10 13,5 20 34 63,3
Emission class due to EN 303-5:2012 5 5 5 5 5 5
Efficiency for power max (%) 88 86 84,6 86 89 82
Efficiency for power min (%) 95 94 94 90 92,2 86,2
CO emission for power max. (mg/m3) 213 221 209 232 327 199
CO emission for power min. (mg/m3) 277 250 277 286 388 454
Voltage (V) 230 230 230 230 400 400
Air flow (m3) 1500 2100 3400 5400 7600 15200
Depth  (mm) 880 880 880 900 1170 1400
Width (mm) 510 510 510 540 710 1000
Height (mm) 1705 1705 1705 1900 2050 2630
Weight (kg) 124,5 125 138 170 380 550
Fuel consumption (kg/h) 4,8 7,5 9,2 16,4 25,25 49,45
TYPE Orte Power24 Orte Power  35 Orte Power  45 Orte Power  80 Orte Power  130 Orte Power  250
Length of the feeder (m) 1,8 1,8 1,8 1,8 1,8 1,8
Ventilator force (W) 499 595 595 635 1785 3585
Max. power consumption (W) 600 711 796 836 1986 3786
Waste gas  temperature for power max. (oC) 190 220 244 220 226 290
Waste gas  temperature for power min. (oC) 80 90 91 130 109 172
Waste gas stream for power max. (g/s) 18 26 28 60 73 167
Waste gas stream for power min. (g/s) 6 9 10 21 30 64
Diameter of the waste gas channel (mm) 150 150 150 150 200 250
Temperature safety limit  (oC) 90 90 90 90 90 90
Chimney draught needed for power max. (Pa) 30 36 38 41 42 50
Chimney draught needed for power min. (Pa) 20 20 20 31 30 36
Required protection (A) 5 5 5 5 10 10
Frequency (Hz) 50 50 50 50 50 50
Noise level within 1 meter (dB) 45 53 56,7 58,4 75,1 77,2
Safety Systems 4 4 4 4 5 5
The minimal amount of air required to proper combustion of the fuel (m3) 80 90 120 225 300 600
FUEL
Pellet s s s s s s
PELLET HOPPER
Standard: 270 liter s s s s s s
Non-standard: 380 liter, 560 liter n n n n n n
External fuel hopper n n n n n n
Fuel fed from the pellet hopper to the burner s s s s s s
BURNER
Steel quality: 1.4828 s s s s s s
Cilindric burner s s s s s s
Furnace made of heat-proof steel s s s s s s
Chute burner s s s s s s
Automatic ash removing s s s s s s
Ventilator s s s s
Pressure Ventilator s s
Gear motor  x 2 pieces s s s s s s
Photocell – flame detection control s s s s s s
Grill for pellet burning s s s s s s
AUTOMATIC EQUIPMENT
Boiler temperature sensor s s s s s s
Burner temperature sensor s s s s s s
Main off-switch s s s s s s
Safety switch s s s s s s
Indicator light s s s s s s
Temperature sensor s s s s s s
Hot water sensor s s s s s s
Enlargement possibility (extra modules) s s s s s s
GSM module or Wi-Fi n n n n n n
AUTOMATIC CONTROLLER – POSSIBILITIES
Feeder steering s s s s s s
Burner feeder controller s s s s s s
Pressure ventilator controller s s s s s s
Igniter controller s s s s s s
Central heating pump controller s s s s s s
Hot water pump controller s s s s s s
Mixing valve controller s s s s s s
Buffer controller s s s s s s
Cooperation with the Wi-Fi module s s s s s s
Weather module controller, solar controller and buffer controller from the controller menu s s s s s s
AUTOMATIC SYSTEMS
5-steps burner modulation s s s s s s
Hot Water priority s s s s s s
Wi-Fi Communication s s s s s s
Fuel choice (3 possibilities) s s s s s s
Alternative function – “boiler mode” s s s s s s
Output testing s s s s s s
Weekly hot water time programming n n n n n n
Weekly room temperature time programming n n n n n n
Simple menu s s s s s s
Advance menu s s s s s s
Alarm codes s s s s s s
Service mode s s s s s s
Multi languages s s s s s s
EXTRA MODULES
Room  temperature sensor n n n n n n
Solar system controller n n n n n n
Steering with three ways mixing valves up to max. 16 units n n n n n n
GSM Module n n n n n n
WIFI Module n n n n n n
Steering via WIFI +  integrated tablet n n n n n n
Steering via GSM/WIFI + integrated tablet n n n n n n

 

s- standard

n- non-standard- optional

 

The Producer reserves the right for technological changes as technical details, size, appearance and accessories of the Air Heater without previously informing the user, as long as it doesn’t meaningful interfere with the functioning of the appliance.

 

 

FOR MORE INFORMATION PLEASE CONTACT OUR SALES DEPARTMENT: +48 604 202 747 or j.kowalska@orte.pl